Transmission pipelines

Equipment subject to technical inspection

 

Technical inspection covers transmission pipelines, in the part forming technical equipment within the meaning of the Technical Inspection Act, for poisonous, caustic and flammable hazardous materials under pressure p > 0.5 bar and with a nominal diameter DN > 25, manufactured or reconstructed after 16 July 2002, intended for:

 

  • compressed gases, liquefied gases, gases dissolved under pressure, vapours and those liquids for which vapour overpressure at the maximum allowable temperature is > 0.5 bar;

  • liquids whose vapour overpressure at the maximum allowable temperature is < 0.5 bar and the product of the allowable overpressure of the liquid and the nominal diameter of the pipeline DN is > 2 000 bar

 

Forms of inspection and deadlines for tests

Type of fluid in the pipeline

Criterion for determining the form of technical inspection

Frequency of tests Operating conditions tests

Frequency of tests Tests with a measuring piston

Form of technical inspection

Gases, excluding natural gas, vapours and those liquids for which vapour overpressure at the maximum allowable temperature is higher than 0.05 MPa

MOP>0.05 MPa and DN>350 or 100350 MPa

1 year

The first test within 4 years from the start of operation and then every 8 years

full

Gases, excluding natural gas, vapours and those liquids for which vapour overpressure at the maximum allowable temperature is higher than 0.05 MPa

MOP>0.05 MPa and 250.05 MPa and 100

An ad hoc check at least every 2 years

Not applicable

limited

Gases, excluding natural gas, vapours and those liquids for which vapour overpressure at the maximum allowable temperature is higher than 0.05 MPa

0.05 MPa

25

Not applicable

Not applicable

simplified

Natural gas

MOP>1.6 MPa and DN>200

An ad hoc check at least every 2 years

Not applicable

limited

Natural gas

other

Not applicable

Not applicable

simplified

Liquids

MOP > 1.0 MPa and DN>25 and MOPxDN>200 MPa

1 year

The first test within 4 years from the start of operation and then every 8 years

full2

Liquids

0.05 MPa200 MPa

An ad hoc check at least every 2 years

Not applicable

limited

1.     Tests with a piston are carried out only in pipelines adapted for such tests.

2.     Pipelines for flammable hazardous liquids with a flash point above 61 °C, qualified on the basis of the specified full inspection criteria should be regarded as falling under limited inspection.

 

 

Required technical documentation

 

Technical documentation of a pipeline submitted by the operator for acceptance tests should be consistent with agreed technical conditions and include at least:

  • design technical documentation of the pipeline and its components,

  • as-built documentation of the pipeline and its components, to the extent specified in the technical conditions,

  • an operating manual for the pipeline,

  • a commissioning manual for the pipeline, if commissioning is planned.

 

The detailed content of the design and as-built technical documentation of a pipeline and its components is specified in agreed technical conditions (i.e. technical specifications other than the technical inspection conditions to be met by pipelines during the design, manufacturing, repair or upgrading referred to in Article 8(7) of the Technical Inspection Act).